Name
Detailed
Felicity Solar Explanation
Rules for product naming
To make it easier for you to understand and choose Felicitysolar products that suit your needs, we have specially worked out the product naming rules for you. Through this naming rule, you will be able to quickly identify key product parameters and features.
Rules for naming batteries
Battery Naming rules
LPBF, LPBA, FLA, FLS: means low voltage battery pack.
FLB: means low voltage battery pack (waterproof series).
FLH: stands for High Voltage Battery Pack.
FLS
FLS48100SCG1
means low voltage battery
48
FLS48100SCG1
Battery voltage, represented by two numbers
12 represents 12.8 V, 24 represents 25.6 V, 48 represents 51.2 V
100
FLS48100SCG1
Battery capacity, expressed in numbers
050 represents 50 Ah, 100 represents 100 Ah
Yes
FLS48100SCG1
Battery model code, represented by one or more letters and numbers.
S means stacking, W means wall mounted, U represents plug-in box, T. suparta tower, B means base, R.
c
FLS48100SCG1
Identification code, represented by a letter
C represents the master control, M represents the slave control, if there is none, leave it blank
G1
FLS48100SCG1
Version number, represented by a letter and a number
G1 represents the first version, G2 represents the second version, and so on
Battery
Rules for naming investors
Investor Naming rules
IVEM, IVCM: means off-grid high frequency inverter.
IVPM: represents industrial frequency inverter with MPPT.
IVPS: means power frequency machine without MPPT.
IVGM: means hybrid inverter.
IVPM
IVPM10048P1G2
represents an industrial frequency inverter with MPPT
100
IVPM10048P1G2
Inverter power, expressed in numbers
100 represents 10000 W, 150 represents 15000 W
48
IVPM10048P1G2
Battery voltage, represented by numbers
12 represents 12 V, 24 represents 24 V, 48 represents 48 V
P1
IVPM10048P1G2
AC side phase, represented by a letter and a number.
P1 represents single phase, P2 represents split phase and P3 represents three phase.
G2
IVPM10048P1G2
Version number, represented by a letter and a number
G1 represents the first version, G2 represents the second version, and so on
IVGM
IVGM
IVGM8KLP2G2-EU
means hybrid inverter
8K
IVGM8KLP2G2-EU
Inverter power, represented by a number and a letter
8K represents 8000W, 20K represents 20000W
l
IVGM8KLP2G2-EU
Battery voltage type, represented by a letter
L represents low voltage (48V), H represents high voltage (≥96V)
P2
IVGM8KLP2G2-EU
AC side phase, represented by a letter and a number.
P1 represents single phase, P2 represents split phase and P3 represents three phase.
G2
IVGM8KLP2G2-EU
Version number, represented by a letter and a number
G1 represents the first version, G2 represents the second version, and so on
EU
IVGM8KLP2G2-EU
Product management number, represented by two letters
EU means Europe, other codes must be indicated; if there are none, leave it blank.
Inverter
IVGM
MPPT Controller Naming Standards
MPPT Rules for naming controllers
SCCM: means MPPT controller.
120
SCCM12048-III
The maximum charging current of the product, expressed in numbers.
150 represents 150 A, 300 represents 300 A.
48
SCCM12048-III
Maximum supported charging voltage, represented by two numbers.
48 represents compatibility with 48V, 24V and 12V.
24 represents 24V and 12V compatibility.
III
SCCM12048-III
Version number, represented by a letter
III represents the third version, and so on