Battery Naming Rules

Battery Naming Rules

LPBF、LPBA、FLA、FLS:stands for low voltage battery pack

FLB:stands for low voltage battery pack (waterproof series)&nbsp

FLH:stands for high voltage battery pack

FLS
FLS48100SCG1
stands for low voltage battery pack
48
FLS48100SCG1
Battery voltage, represented by two numbers 12 represents 12.8V, 24 represents 25.6V, 48 represents 51.2V
100
FLS48100SCG1
Battery capacity, expressed in numbers 050 represents 50Ah, 100 represents 100Ah
S
FLS48100SCG1
Battery pack model code, represented by one or more letters and numbers S significa apilamiento, W significa montado en la pared, U representa la caja enchufable, T. Suparta la torre, B significa base, R.
C
FLS48100SCG1
Identification code, represented by a letter C represents the master control, M represents the slave control, if there is no, leave it blank
G1
FLS48100SCG1
Version number, represented by a letter and a number G1 represents the first version, G2 represents the second version, and so on

Battery

Inverter Naming Rules

Inverter Naming Rules

IVEM、IVCM:stands for high-frequency off-grid inverter

IVPM:represents industrial frequency inverter with MPPT&nbsp

IVPS:stands for industrial frequency machine without MPPT

IVGM:stands for hybrid inverter

IVPM
IVPM10048P1G2
represents industrial frequency inverter with MPPT
100
IVPM10048P1G2
Inverter power, expressed in numbers 100 represents 10000W, 150 represents 15000W
48
IVPM10048P1G2
Battery voltage, represented by numbers 12 represents 12V, 24 represents 24V, 48 represents 48V
P1
IVPM10048P1G2
AC side phase, represented by a letter and a number P1 represents single phase, P2 represents split phase, P3 represents three phase
G2
IVPM10048P1G2
Version number, represented by a letter and a number G1 represents the first version, G2 represents the second version, and so on

IVGM

IVGM
IVGM8KLP2G2-EU
stands for hybrid inverter
8K
IVGM8KLP2G2-EU
Inverter power, represented by a number and a letter 8K represents 8000W, 20K represents 20000W
L
IVGM8KLP2G2-EU
Battery voltage type, represented by a letter L represents low voltage (48V), H represents high voltage (≥96V)
P2
IVGM8KLP2G2-EU
AC side phase, represented by a letter and a number P1 represents single phase, P2 represents split phase, P3 represents three phase
G2
IVGM8KLP2G2-EU
Version number, represented by a letter and a number G1 represents the first version, G2 represents the second version, and so on
EU
IVGM8KLP2G2-EU
Product management number, represented by two letters EU stands for Europe, other codes are to be named, if none, leave it blank

Inverter

IVGM

MPPT Controller Naming Rules

MPPT Controller Naming Rules

SCCM:stands for MPPT controller

120
SCCM12048-III
The maximum charging current of the product, expressed in numbers 150 represents 150A, 300 represents 300A
48
SCCM12048-III
Compatible maximum charging voltage, represented by two numbers 48 represents compatible with 48V, 24V, 12V 24 represents compatible with 24V, 12V
III
SCCM12048-III
Version number, represented by a letter III represents the third version, and so on

MPPT

MPPT